Transformers - Product Range
You
will need Adobe Acrobat Reader(4.0 or above) to read the Catalogue. If you do
not have it, download it here.

The Transformers are briefly classified as below:-
|
DISTRIBUTION
TRANSFORMERS
As the name
suggests, these are exclusively used for supplying power to end users.
Range : 500 KVA
to 5000 KVA, up to 33 kV class.
Related Links:- Download
Catalogue |
|
|
|
|
|
POWER
TRANSFORMERS
Range : Up
to 200 MVA, up to 220 kV class
Unique features of our Power
Transformers :
-
For Power transformers, the
short circuit withstand capability is of prime importance. This is achieved by
us through the adoption of a unique clamping arrangement of the windings and
accurately determined pre-stress
-
For primary voltages of 132 kV
and 220 kV, ability to withstand system transients and lightning surges are
vital parameters. The insulation design and quality of materials used, ensure
that our product can withstand the most adverse conditions
-
Testing means to us much more
than meeting contractual and "standards" obligations. Several in-house tests
have been devised by us to ensure quality and reliability in service. For this,
we have a variety of testing equipment, full fledged laboratory and trained
personnel
Related Links:-
Download
Catalogue |
|

Power Transformer - Class 132 KV
|

Power Transformer - Class
220 KV
|
|
GENERATOR TRANSFORMERS
This is a type of
Power Transformer where the primary winding is connected to the generator and
secondary to the transmission system. In addition to the features of Power
Transformers, the magnetic circuit is designed such that our Generator
Transformer can withstand over voltages up to 170 %.
Related Links:-
Download
Catalogue |
SPECIAL
TRANSFORMERS
These
transformers are specially designed and manufactured for dedicated
applications.They provide trouble free operation even during the most demanding
working conditions.
|
|
-
MOTOR
STARTING TRANSFORMERS
These are used for starting large induction or synchronous motors. The unique
feature of these transformers is they function as Auto Transformers during
starting and then function as reactors. In this method of starting the inrush
current is reduced and thus the voltage dip is also reduced. Special types of
windings and a unique construction of the magnetic core are used. The core
consists of several lamination packets assembled one over the other with an air
gap between each packet.
-
DRY
TYPE TRANSFORMERS
Instead of mineral oil, these transformers have air as the medium of insulation
and heat dissipation. These are nonflammable, maintenance free transformers
which can be installed at the load center in enclosed areas. Bringing the HT
line to the load center reduces the line losses.
-
THYRISTOR
DUTY TRANSFORMERS
Used where high power D C is required e.g. Chemical and Steel Industry. The
primary side is connected to the supply system and secondary side to thyristor
for conversion form A.C to D.C. As output current is non - sinusoidal, the
effect produced in the electric and magnetic circuit differs from conventional
transformers. Some unique features are as under :-
-
There are two secondary windings
arranged axially one over the other with the corresponding primary winding
connected in parallel. This ensures identical impedence between primary and
each individual secondary winding, which is of utmost importance for
satisfactory operation
-
Magnetic circuit is specially
designed to ensure that it never goes into saturation
-
The style of windings and
cooling system is such that due to the over heating and high stray loss
produced by the non-sinusoidal current, the hot spot temperature is well within
the permissible limits.
-
LOCOMOTIVE
TRANSFORMERS
Locomotive Transformers are mounted directly on the locomotives used for
hauling passenger and goods trains. These transformers are required to meet
large voltage variations, sustained over loads, frequent short circuits and
excessive vibrations. To achieve the mechanical strength required to withstand
innumerable short circuits, the windings are rectangular which in-turn reduces
the axial forces. Sandwiching of the primary and secondary windings reduces the
radial forces. Adequate sizing of cooling ducts, adoption of appropriate
current densities and direct oil flow ensure transformer protection during
conditions of overload. The clamping system of the windings takes care of the
mechanical vibrations and the effect of short circuit. Till date, we have
several transformers operating satisfactory in service.